TAKFLY COMMUNICATIONS CO., LTD.

Make FTTH spread all over the world, and make better connectivity for a better life

Manufacturer from China
Verified Supplier
5 Years
Home / Products / Optical Transceiver Module /

100Gbps QSFP28 SR4 850nm 100m MPO with DDM Transceiver Up to 27.952 Gbps Data rate per channel

Contact Now
TAKFLY COMMUNICATIONS CO., LTD.
Visit Website
City:shenzhen
Country/Region:china
Contact Person:Sales Director Jessica Liao
Contact Now

100Gbps QSFP28 SR4 850nm 100m MPO with DDM Transceiver Up to 27.952 Gbps Data rate per channel

Ask Latest Price
Video Channel
Brand Name :TAKFLY
Model Number :TKQS28-100G-SR4
Certification :CE,ROHS,REACH,ISO9001,ISO14001
Place of Origin :Guangdong, SHENZHEN
MOQ :1 Pices
Price :US$0.01 ~ US$1200/PC
Payment Terms :L/C,D/A,D/P,T/T,Western Union,MoneyGram
Delivery Time :3-7working days
Ratio :50/50
Center Wavelength :1450nm
Insertion Loss :≤0.3dB
Package Weight :10g
Package Type :Bare Fiber, 900um Loose Tube, 2mm Cable
Wavelegth :1310nm
Axis Alignment :Slow axis or Fast axis
Wavelength Range :1310nm, 1550nm
Application :Optical Communication Systems
Splitter Ratio :98/2
Storage Temperature :-40~+85℃
Port Number :1x2
Fiber Length :1m
Fiber :PM Corning 980nm fiber
Power Handling Capacity :High Power
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description
Description
  • TKQS28-100G-SR4 are designed for use in 100 Gigabit per second links over multimode fiber. They are compliant with the QSFP28 MSA and IEEE 802.3bm
  • The optical transmitter portion of the transceiver incorporates a 4-channel VCSEL (Vertical Cavity Surface Emitting Laser) array, a 4-channel input buffer and laser driver, diagnostic monitors, control and bias blocks. For module control, the control interface incorporates a Two Wire Serial interface of clock and data signals. Diagnostic monitors for VCSEL bias, module temperature, transmitted optical power,received optical power and supply voltage are implemented and results are available through the TWS interface. Alarm and warning thresholds are established for the monitored attributes. Flags are set and interrupts generated when the attributes are outside the thresholds. Flags are also set and interrupts generated for loss of input signal (LOS) and transmitter fault conditions. All flags are latched and will remain set even if the condition initiating the latch clears and operation resumes. All interrupts can be masked and flags are reset by reading the appropriate flag register. The optical output will squelch for loss of input signal unless squelch is disabled. Fault detection or channel deactivation through the TWS interface will disable the channel. Status, alarm/warning and fault information are available via the TWS interface.
  • The optical receiver portion of the transceiver incorporates a 4-channel PIN photodiode array, a 4-channel TIA array, a 4 channel output buffer, diagnostic monitors, and control and bias blocks. Diagnostic monitors for optical input power are implemented and results are available through the TWS interface. Alarm and warning thresholds are established for the monitored attributes. Flags are set and interrupts generated when the attributes are outside the thresholds. Flags are also set and interrupts generated for loss of optical input signal (LOS). All flags are latched and will remain set even if the condition initiating the flag clears and operation resumes. All interrupts can be masked and flags are reset upon reading the appropriate flag register. The electrical output will squelch for loss of input signal (unless squelch is disabled) and channel de-activation through TWS interface. Status and alarm/warning information are available via the TWS interface.

Features

Ø Up to 27.952 Gbps Data rate per channel

Ø Maximum link length of 100m links on OM3 multimode fiber

Ø High Reliability 850nm VCSEL technology

Ø Electrically hot-pluggable

Ø Digital diagnostic SFF-8436 compliant

Ø Compliant with QSFP28 MSA

Ø Case operating temperature range:0°C to 70°C

Ø Power dissipation < 2.5 W


Applications

Ø Data center

Ø Infiniband QDR

Ø Fiber channel


Standard

Ø Compliant to IEEE 802.3 bm

Ø Compliant to SFF-8436

Ø RoHS Compliant.


Absolute Maximum Ratings

Parameter

Symbol

Min.

Typ.

Max.

Unit

Note

Storage Temperature

Ts

-40

-

85

ºC

Relative Humidity

RH

5

-

95

%

Power Supply Voltage

VCC

-0.3

-

4

V

Signal Input Voltage

Vcc-0.3

-

Vcc+0.3

V



Recommended Operating Conditions

Parameter

Symbol

Min.

Typ.

Max.

Unit

Note

Case Operating Temperature

Tcase

0

-

70

ºC

Without air flow

Power Supply Voltage

VCC

3.14

3.3

3.46

V

Power Supply Current

ICC

-

750

mA

Data Rate

BR

25.78125

Gbps

Each channel

Transmission Distance

TD

-

100

m

OM3 MMF

Electrical Specifications

Parameter

Symbol

Min

Typ

Max

Unit

Note

Supply Voltage

Vcc

3.14

3.3

3.46

V

Supply Current

Icc

750

mA

Transmitter

Input differential impedance

Rin

100

Ω

1

Differential data input swing

Vin,pp

180

1000

mV

Single ended input voltage tolerance

VinT

-0.3

4.0

V

Receiver

Differential data output swing

Vout,pp

300

850

mV

2

Single-ended output voltage

-0.3

4.0

V

Notes:

1. Connected directly to TX data input pins. AC coupled thereafter.

2. Into 100Ω ohms differential termination.


Optical Characteristics

Parameter

Symbol

Min

Typ

Max

Unit

Note

Transmitter

Center Wavelength

λ0

840

860

nm

Average Launch Power each lane

-8.4

2.4

dBm

Spectral Width (RMS)

σ

0.6

nm

Optical Extinction Ratio

ER

2

dB

Transmitter and Dispersion Penalty each lane

TDP

4.3

dB

Optical Return Loss Tolerance

ORL

12

dB

Output Eye Mask

Compliant with IEEE 802.3bm

Receiver

Receiver Wavelength

λin

840

860

nm

Rx Sensitivity per lane

RSENS

-10.3

dBm

1

Input Saturation Power (Overload)

Psat

2.4

dBm

Receiver Reflectance

Rr

-12

dB

Notes:

1. Measured with a PRBS 231-1 test pattern, @25.78Gb/s, BER<10-12 .


Pin Assignment

100Gbps QSFP28 SR4 850nm 100m MPO with DDM Transceiver Up to 27.952 Gbps Data rate per channel

Figure 1---Pin out of Connector Block on Host Board

Pin

Symbol

Name/Description

Note

1

GND

Transmitter Ground (Common with Receiver Ground)

1

2

Tx2n

Transmitter Inverted Data Input

3

Tx2p

Transmitter Non-Inverted Data output

4

GND

Transmitter Ground (Common with Receiver Ground)

1

5

Tx4n

Transmitter Inverted Data Input

6

Tx4p

Transmitter Non-Inverted Data output

7

GND

Transmitter Ground (Common with Receiver Ground)

1

8

ModSelL

Module Select

9

ResetL

Module Reset

10

VccRx

3.3V Power Supply Receiver

2

11

SCL

2-Wire serial Interface Clock

12

SDA

2-Wire serial Interface Data

13

GND

Transmitter Ground (Common with Receiver Ground)

14

Rx3p

Receiver Non-Inverted Data Output

15

Rx3n

Receiver Inverted Data Output

16

GND

Transmitter Ground (Common with Receiver Ground)

1

17

Rx1p

Receiver Non-Inverted Data Output

18

Rx1n

Receiver Inverted Data Output

19

GND

Transmitter Ground (Common with Receiver Ground)

1

20

GND

Transmitter Ground (Common with Receiver Ground)

1

21

Rx2n

Receiver Inverted Data Output

22

Rx2p

Receiver Non-Inverted Data Output

23

GND

Transmitter Ground (Common with Receiver Ground)

1

24

Rx4n

Receiver Inverted Data Output

1

25

Rx4p

Receiver Non-Inverted Data Output

26

GND

Transmitter Ground (Common with Receiver Ground)

1

27

ModPrsl

Module Present

28

IntL

Interrupt

29

VccTx

3.3V power supply transmitter

2

30

Vcc1

3.3V power supply

2

31

LPMode

Low Power Mode,not connect

32

GND

Transmitter Ground (Common with Receiver Ground)

1

33

Tx3p

Transmitter Non-Inverted Data Input

34

Tx3n

Transmitter Inverted Data Output

35

GND

Transmitter Ground (Common with Receiver Ground)

1

36

Tx1p

Transmitter Non-Inverted Data Input

37

Tx1n

Transmitter Inverted Data Output

38

GND

Transmitter Ground (Common with Receiver Ground)

1

Notes:

1. GND is the symbol for signal and supply (power) common for QSFP28 modules. All are common within the QSFP28 module and all module voltages are referenced to this potential unless otherwise noted. Connect these directly to the host board signal common ground plane.

2. VccRx, Vcc1 and VccTx are the receiving and transmission power suppliers and shall be applied concurrently. Recommended host board power supply filtering is shown below. Vcc Rx, Vcc1 and Vcc Tx may be internally connected within the QSFP28 transceiver module in any combination. The connector pins are each rated for a maximum current of 500mA


Digital Diagnostic Functions

TKQS28-100G-SR4 support the 2-wire serial communication protocol as defined in the QSFP28 MSA., which allows real-time access to the following operating parameters

Ÿ Transceiver temperature

Ÿ Laser bias current

Ÿ Transmitted optical power

Ÿ Received optical power

Ÿ Transceiver supply voltage

It also provides a sophisticated system of alarm and warning flags, which may be used to alert end-users when particular operating parameters are outside of a factory-set normal range.

The operating and diagnostics information is monitored and reported by a Digital Diagnostics Transceiver Controller inside the transceiver, which is accessed through the 2-wire serial interface. When the serial protocol is activated, the serial clock signal (SCL pin) is generated by the host. The positive edge clocks data into the QSFP28 transceiver into those segments of its memory map that are not write-protected.

The negative edge clocks data from the QSFP28 transceiver. The serial data signal (SDA pin) is bi-directional for serial data transfer. The host uses SDA in conjunction with SCL to mark the start and end of serial protocol activation. The memories are organized as a series of 8-bit data words that can be addressed individually or sequentially. The 2-wire serial interface provides sequential or random access to the 8 bit parameters, addressed from 00h to the maximum address of the memory.

This clause defines the Memory Map for QSFP28 transceiver used for serial ID, digital monitoring and certain control functions. The interface is mandatory for all QSFP28 devices. The memory map has been changed in order to accommodate 4 optical channels and limit the required memory space. The structure of the memory is shown in Figure 2 -QSFP28 Memory Map. The memory space is arranged into a lower, single page, address space of 128 bytes and multiple upper address space pages. This structure permits timely access to addresses in the lower page, e.g. Interrupt Flags and Monitors. Less time critical entries, e.g. serial ID information and threshold settings, are available with the Page Select function. The structure also provides address expansion by adding additional upper pages as needed. For example, in Figure 2 upper pages 01 and 02 are optional. Upper page 01 allows implementation of Application Select Table, and upper page 02 provides user read/write space. The lower page and upper pages 00 and 03 are always implemented. The interface address used is A0xh and is mainly used for time critical data like interrupt handling in order to enable a “one-time-read” for all data related to an interrupt situation. After an Interrupt, IntL, has been asserted, the host can read out the flag field to determine the effected channel and type of flag.

For more detailed information including memory map definitions, please see the QSFP28 MSA Specification.

Figure 2 QSFP28 Memory Map

100Gbps QSFP28 SR4 850nm 100m MPO with DDM Transceiver Up to 27.952 Gbps Data rate per channel


Lower Memory Map

The lower 128 bytes of the 2-wire serial bus address space, see Table 1, is used to access a variety of

measurements and diagnostic functions, a set of control functions, and a means to select which of the various upper memory map pages are accessed on subsequent reads. This portion of the address space is always directly addressable and thus is chosen for monitoring and control functions that may need to be repeatedly accessed. The definition of identifier field is the same as page 00h Byte 128.


Table 1Lower Memory Map

Byte Address Byte AddressByte Address

Description

Type

0

Identifier (1 Byte)

Read-Only

1-2

Status (2 Bytes)

Read-Only

3-21

Interrupt Flags (19 Bytes)

Read-Only

22-33

Module Monitors (12 Bytes)

Read-Only

34-81

Channel Monitors (48 Bytes)

Read-Only

82-85

Reserved (4 Bytes)

Read-Only

86-97

Control (12 Bytes)

Read/Write

98-99

Reserved (2 Bytes)

Read/Write

100-106

Module and Channel Masks (7 Bytes)

Read/Write

107-118

Reserved (12 Bytes)

Read/Write

119-122

Password Change Entry Area (optional) (4 Bytes)

Read/Write

123-126

Password Entry Area (optional) (4 Bytes)

Read/Write

127

Page Select Byte

Read/Write



Status Indicator Bits

The Status Indicators are defined in Table 2.

Table 2 Status Indicators

Byte

Bit

Name

Description

1

All

Reserved

2

7

Reserved

6

Reserved

5

Reserved

4

Reserved

3

Reserved

2

Reserved

1

IntL

Digital state of the IntL interrupt output pin.

0

Data_Not_Ready

Indicates transceiver has not yet achieved power up and monitor data is not ready. Bit remains high until data is ready to be read at which time the device sets the bit low.


Interrupt Flags

A portion of the memory map (Bytes 3 through 21), form a flag field. Within this field, the status of LOS and Tx Fault as well as alarms and warnings for the various monitored items is reported. For normal operation and default state, the bits in this field have the value of 0b. For the defined conditions of LOS, Tx Fault, module and channel alarms and warnings, the appropriate bit or bits are set, value = 1b. Once asserted, the bits remained set (latched) until cleared by a read operation that includes the affected bit or reset by the ResetL pin. The Channel Status Interrupt Flags are defined in Table 3.


Table 3 — Channel Status Interrupt Flags

Byte

Bit

Name

Description

3

7

L-Tx4 LOS

Latched TX LOS indicator, channel 4 (Not support)

6

L-Tx3 LOS

Latched TX LOS indicator, channel 3 (Not support)

5

L-Tx2 LOS

Latched TX LOS indicator, channel 2 (Not support)

4

L-Tx1 LOS

Latched TX LOS indicator, channel 1 (Not support)

3

L-Rx4 LOS

Latched RX LOS indicator, channel 4

2

L-Rx3 LOS

Latched RX LOS indicator, channel 3

1

L-Rx2 LOS

Latched RX LOS indicator, channel 2

0

L-Rx1 LOS

Latched RX LOS indicator, channel 1

4

7-4

Reserved

3

L-Tx4 Fault

Latched TX fault indicator, channel 4

2

L-Tx3 Fault

Latched TX fault indicator, channel 3

1

L-Tx2 Fault

Latched TX fault indicator, channel 2

0

L-Tx1 Fault

Latched TX fault indicator, channel 1

5

All

Reserved

The Module Monitor Interrupt Flags are defined in Table 4.

Table 4 Module Monitor Interrupt Flags

Byte

Bit

Name

Description

6

7

L-Temp High Alarm

Latched high temperature alarm

6

L-Temp Low Alarm

Latched low temperature alarm

5

L-Temp High Warning

Latched high temperature warning

4

L-Temp Low Warning

Latched low temperature warning

3-0

Reserved

7

7

L-Vcc High Alarm

Latched high supply voltage alarm

6

L-Vcc Low Alarm

Latched low supply voltage alarm

5

L-Vcc High Warning

Latched high supply voltage warning

4

L-Vcc Low Warning

Latched low supply voltage warning

3-0

Reserved

8

All

Reserved

The Channel Monitor Interrupt Flags are defined in Table 5

Table 5 Channel Monitor Interrupt Flags

Byte

Bit

Name

Description

9

7

L-Rx1 Power High Alarm

Latched high RX power alarm, channel 1

6

L-Rx1 Power Low Alarm

Latched low RX power alarm, channel 1

5

L-Rx1 Power High Warning

Latched high RX power warning, channel 1

4

L-Rx1 Power Low Warning

Latched low RX power warning, channel 1

3

L-Rx2 Power High Alarm

Latched high RX power alarm, channel 2

2

L-Rx2 Power Low Alarm

Latched low RX power alarm, channel 2

1

L-Rx2 Power High Warning

Latched high RX power warning, channel 2

0

L-Rx2 Power Low Warning

Latched low RX power warning, channel 2

10

7

L-Rx3 Power High Alarm

Latched high RX power alarm, channel 3

6

L-Rx3 Power Low Alarm

Latched low RX power alarm, channel 3

5

L-Rx3 Power High Warning

Latched high RX power warning, channel 3

4

L-Rx3 Power Low Warning

Latched low RX power warning, channel 3

3

L-Rx4 Power High Alarm

Latched high RX power alarm, channel 4

2

L-Rx4 Power Low Alarm

Latched low RX power alarm, channel 4

1

L-Rx4 Power High Warning

Latched high RX power warning, channel 4

0

L-Rx4 Power Low Warning

Latched low RX power warning, channel 4

11

7

L-Tx1 Bias High Alarm

Latched high TX bias alarm, channel 1

6

L-Tx1 Bias Low Alarm

Latched low TX bias alarm, channel 1

5

L-Tx1 Bias High Warning

Latched high TX bias warning, channel 1

4

L-Tx1 Bias Low Warning

Latched low TX bias warning, channel 1

3

L-Tx2 Bias High Alarm

Latched high TX bias alarm, channel 2

2

L-Tx2 Bias Low Alarm

Latched low TX bias alarm, channel 2

1

L-Tx2 Bias High Warning

Latched high TX bias warning, channel 2

0

L-Tx2 Bias Low Warning

Latched low TX bias warning, channel 2

12

7

L-Tx3 Bias High Alarm

Latched high TX bias alarm, channel 3

6

L-Tx3 Bias Low Alarm

Latched low TX bias alarm, channel 3

5

L-Tx3 Bias High Warning

Latched high TX bias warning, channel 3

4

L-Tx3 Bias Low Warning

Latched low TX bias warning, channel 3

3

L-Tx4 Bias High Alarm

Latched high TX bias alarm, channel 4

2

L-Tx4 Bias Low Alarm

Latched low TX bias alarm, channel 4

1

L-Tx4 Bias High Warning

Latched high TX bias warning, channel 4

0

L-Tx4 Bias Low Warning

Latched low TX bias warning, channel 4

13

7

L-Tx1 Power High Alarm

Latched high TX Power alarm, channel 1

6

L-Tx1 Power Low Alarm

Latched low TX Power alarm, channel 1

5

L-Tx1 Power High Warning

Latched high TX Power warning, channel 1

4

L-Tx1 Power Low Warning

Latched low TX Power warning, channel 1

3

L-Tx2 Power High Alarm

Latched high TX Power alarm, channel 2

2

L-Tx2 Power Low Alarm

Latched low TX Power alarm, channel 2

1

L-Tx2 Power High Warning

Latched high TX Power warning, channel 2

0

L-Tx2 Power Low Warning

Latched low TX Power warning, channel 2

14

7

L-Tx3 Power High Alarm

Latched high TX Power alarm, channel 3

6

L-Tx3 Power Low Alarm

Latched low TX Power alarm, channel 3

5

L-Tx31 Power High Warning

Latched high TX Power warning, channel 3

4

L-Tx3 Power Low Warning

Latched low TX Power warning, channel 3

3

L-Tx4 Power High Alarm

Latched high TX Power alarm, channel 4

2

L-Tx4 Power Low Alarm

Latched low TX Power alarm, channel 4

1

L-Tx4 Power High Warning

Latched high TX Power warning, channel 4

0

L-Tx4 Power Low Warning

Latched low TX Power warning, channel 4

15-16

All

Reserved

Reserved channel monitor flags, set 4

17-18

All

Reserved

Reserved channel monitor flags, set 5

19-20

All

Reserved

Reserved channel monitor flags, set 6

21

All

Reserved

Module Monitors

Real time monitoring for the QSFP28 module include transceiver temperature, transceiver supply voltage, and monitoring for each transmit and receive channel. Measured parameters are reported in 16-bit data fields, i.e., two concatenated bytes. These are shown in Table 6.

Table 6 Module Monitoring Values

Byte

Bit

Name

Description

22

All

Temperature MSB

Internally measured module temperature

23

All

Temperature LSB

24-25

All

Reserved

26

All

Supply Voltage MSB

Internally measured module supply voltage

27

All

Supply Voltage LSB

28-33

All

Reserved

Channel Monitoring

Real time channel monitoring is for each transmit and receive channel and includes optical input power ,Tx bias current and Tx output Power. Measurements are calibrated over vendor specified operating temperature and voltage and should be interpreted as defined below. Alarm and warning threshold values should be interpreted in the same manner as real time 16-bit data. Table 7 defines the Channel Monitoring.

Table 7Channel Monitoring Values

Byte

Bit

Name

Description

34

All

Rx1 Power MSB

Internally measured RX input power, channel 1

35

All

Rx1 Power LSB

36

All

Rx2 Power MSB

Internally measured RX input power, channel 2

37

All

Rx2 Power LSB

38

All

Rx3 Power MSB

Internally measured RX input power, channel 3

39

All

Rx3 Power LSB

40

All

Rx4 Power MSB

Internally measured RX input power, channel 4

41

All

Rx4 Power LSB

42

All

Tx1 Bias MSB

Internally measured TX bias, channel 1

43

All

Tx1 Bias LSB

44

All

Tx2 Bias MSB

Internally measured TX bias, channel 2

45

All

Tx2 Bias LSB

46

All

Tx3 Bias MSB

Internally measured TX bias, channel 3

47

All

Tx3 Bias LSB

48

All

Tx4 Bias MSB

Internally measured TX bias, channel 4

49

All

Tx4 Bias LSB

50

All

Tx1 Power MSB

Internally measured TX output power, channel 1

51

All

Tx1 Power LSB

52

All

Tx2 Power MSB

Internally measured TX output power, channel 2

53

All

Tx2 Power LSB

54

All

Tx3 Power MSB

Internally measured TX output power, channel 3

55

All

Tx3 Power LSB

56

All

Tx4 Power MSB

Internally measured TX output power, channel 4

57

All

Tx4 Power LSB

58-65

Reserved channel monitor set 4

66-73

Reserved channel monitor set 5

74-81

Reserved channel monitor set 6

Control Bytes

Control Bytes are defined in Table 8.

Table 8 Control Bytes

Byte

Bit

Name

Description

86

7-4

Reserved

3

Tx4_Disable

Read/write bit that allows software disable of transmitters

2

Tx3_Disable

Read/write bit that allows software disable of transmitters

1

Tx2_Disable

Read/write bit that allows software disable of transmitters

0

Tx1_Disable

Read/write bit that allows software disable of transmitters

87

7

Rx4_Rate_Select

Software Rate Select, Rx channel 4 msb

6

Rx4_Rate_Select

Software Rate Select, Rx channel 4 lsb

5

Rx3_Rate_Select

Software Rate Select, Rx channel 3 msb

4

Rx3_Rate_Select

Software Rate Select, Rx channel 3 lsb

3

Rx2_Rate_Select

Software Rate Select, Rx channel 2 msb

2

Rx2_Rate_Select

Software Rate Select, Rx channel 2 lsb

1

Rx1_Rate_Select

Software Rate Select, Rx channel 1 msb

0

Rx1_Rate_Select

Software Rate Select, Rx channel 1 lsb

88

7

Tx4_Rate_Select

Software Rate Select, Tx channel 4 msb (Not support)

6

Tx4_Rate_Select

Software Rate Select, Tx channel 4 lsb (Not support)

5

Tx3_Rate_Select

Software Rate Select, Tx channel 3 msb (Not support)

4

Tx3_Rate_Select

Software Rate Select, Tx channel 3 lsb (Not support)

3

Tx2_Rate_Select

Software Rate Select, Tx channel 2 msb (Not support)

2

Tx2_Rate_Select

Software Rate Select, Tx channel 2 lsb (Not support)

1

Tx1_Rate_Select

Software Rate Select, Tx channel 1 msb (Not support)

0

Tx1_Rate_Select

Software Rate Select, Tx channel 1 lsb (Not support)

89

All

Rx4_Application_Select

Software Application Select per SFF-8079, Rx Channel 4

90

All

Rx3_Application_Select

Software Application Select per SFF-8079, Rx Channel 3

91

All

Rx2_Application_Select

Software Application Select per SFF-8079, Rx Channel 2

92

All

Rx1_Application_Select

Software Application Select per SFF-8079, Rx Channel 1

93

2-7

Reserved

1

Power_set

Power set to low power mode. Default 0.

0

Power_over-ride

Override of LPMode signal setting the power mode with software.

94

All

Tx4_Application_Select

Software Application Select per SFF-8079, Tx Channel 4 (Not support)

95

All

Tx3_Application_Select

Software Application Select per SFF-8079, Tx Channel 3 (Not support)

96

All

Tx2_Application_Select

Software Application Select per SFF-8079, Tx Channel 2 (Not support)

97

All

Tx1_Application_Select

Software Application Select per SFF-8079, Tx Channel 1 (Not support)

98-99

All

Reserved



Host - Transceiver Interface Block

100Gbps QSFP28 SR4 850nm 100m MPO with DDM Transceiver Up to 27.952 Gbps Data rate per channel

Outline Dimensions

100Gbps QSFP28 SR4 850nm 100m MPO with DDM Transceiver Up to 27.952 Gbps Data rate per channel

Outline Dimensions

Feature

Reference

Performance

Electrostatic discharge (ESD)

IEC/EN 61000-4-2

Compatible with standards

Electromagnetic Interference (EMI)

FCC Part 15 Class B EN 55022 Class B (CISPR 22A)

Compatible with standards

Laser Eye Safety

FDA 21CFR 1040.10, 1040.11 IEC/EN 60825-1, 2

Class 1 laser product

Component Recognition

IEC/EN 60950, UL

Compatible with standards

ROHS

2002/95/EC

Compatible with standards

EMC

EN61000-3

Compatible with standards


Inquiry Cart 0